CISA Warns of OpenPLC and libumqtt Industrial Flaws

The US Cybersecurity and Infrastructure Security Agency has warned of serious flaws in two pieces of software used in industrial and connected systems, after issuing industrial control system advisories on 19 November. One flaw lets an unauthenticated attacker create administrator accounts on OpenPLC Runtime controllers. The other, in the libumqtt messaging library, has no fix at all.
CISA said it had received no reports of known public exploitation specifically targeting either vulnerability at the time of its advisories. But both flaws sit in systems that run factories, energy networks, transport and water infrastructure, where a successful attack can have physical consequences.
OpenPLC Runtime: race condition creates admin accounts
The first flaw, tracked as CVE-2026-126088, affects Autonomy Logic OpenPLC Runtime versions 4.2.4 and earlier. It is a race condition: when several requests arrive at the same time, they can all pass the check for whether a user account already exists before any of them is saved, so several unauthenticated administrator accounts can be created.
CISA scores the flaw 8.1 out of 10 under CVSS version 3, while a separate assessment puts it at 9.2 under CVSS version 4. The flaw was reported by researcher Noureddin Lutfi. OpenPLC Runtime is used in critical manufacturing, energy, transportation systems, and water and wastewater systems, and is deployed worldwide.
The fix is straightforward: update to OpenPLC Runtime version 4.3.0 or later. Until the update is applied, the runtime's web interface should not be exposed to untrusted networks, and administrators should check for administrator accounts they did not create.
libumqtt: integer underflow with no fix available
The second flaw, CVE-2026-125132, affects libumqtt versions 1.1.1 and earlier. The lightweight MQTT library is used in connected devices and industrial builds. CISA says the product is vulnerable to an integer underflow that may allow a remote attacker to cause a denial of service, memory corruption, or information disclosure. It scores 8.6 out of 10.
The flaw was reported by researcher Joseph Devasia. Unlike OpenPLC, there is no vendor fix: CISA says the repository owners did not respond to its request for coordination, and the advisory lists no remediation. Users are encouraged to contact the project for support. The library is deployed in critical manufacturing, energy, information technology, transportation systems, and water and wastewater sectors.
With no patch to apply, the only defence is isolation. Systems using libumqtt should be placed behind firewalls, with web and remote access blocked where possible, and monitored for unusual traffic or crashes that could signal an attempted exploit.
What operators should do now
The two advisories were issued alongside a third covering trailer-brake controllers, as part of CISA's regular industrial control system warnings. The pattern is familiar: open-source components widely reused in operational technology, one with a fix that needs applying and one where the project has gone quiet.
Operators running OpenPLC should upgrade to version 4.3.0 or later and audit administrator accounts. Anyone using libumqtt should assume the flaw stays open, segment the affected systems away from the internet and from business networks, and plan a migration to a maintained messaging library. Both flaws are a reminder that the software inside industrial equipment needs the same patching discipline as office IT, even when the vendor is a small open-source project.