CVE-2026-123903: vCenter auth bypass patched

Broadcom has patched a second critical authentication bypass in VMware vCenter in less than a week, warning that teams who applied last week's emergency fix still need to update again. The new flaw, CVE-2026-123903, is rated 9.8 out of 10 on the CVSS severity scale and sits in the VMware Directory Service, known as vmdir, the directory behind vCenter's single sign-on system. Broadcom disclosed it on 24 November 2026 in security advisory VMSA-2026-0011, which covers 23 vulnerabilities across vCenter, ESX, Workstation, Fusion, VMware Tools and Avi Load Balancer.
A malicious actor with network access to vCenter could exploit the flaw to bypass authentication and gain unauthorised access to the system, Broadcom said. No login credentials are needed, and no user interaction is required. The directory service holds the identities that vCenter trusts, so bypassing it can open the door to the management layer of an entire virtual estate — the hosts, the virtual machines and the storage and network settings they depend on.
A second flaw in the same component
The timing is what makes this patch awkward for administrators. On 19 November, Broadcom shipped VMSA-2026-0009 to fix CVE-2026-123890, a different authentication bypass in the same vmdir component that had been exploited as a zero-day by a suspected China-nexus espionage group known as Armory Castle. Broadcom says CVE-2026-123903 is a distinct issue, not related to that flaw — researchers note it is reachable over LDAP, while the earlier flaw was reachable over RPC — but teams running vCenter 9.x who installed last week's emergency builds are not covered against the new one and need a second update.
The fixed releases are vCenter 9.1.2 for the 9.1 line, the 9.0.2.0300 express patch for the 9.0 line, vCenter 8.0 U3m, and Cloud Foundation 5.2.5. Systems already on vCenter 8.0 U3m from last week's patching are covered for both flaws and need no further update. The hardest case is vCenter 7.0, which Broadcom lists as affected but offers fixes for only through an extended support contract; there is no public patch for other 7.0 deployments. Broadcom lists no workaround for CVE-2026-123903, so patching is the only vendor-supported remedy.
No exploitation reported — but a proof of concept exists
Broadcom has not reported any exploitation of CVE-2026-123903, and the flaw is not in CISA's Known Exploited Vulnerabilities catalogue. That does not mean teams can wait. A public proof-of-concept exploit is available and has been validated by security firm Rapid7, and attackers are already known to target the directory service — the earlier flaw was exploited in the wild within days of disclosure. Broadcom credited researchers from QiAnXin, DepthFirst and ThreatBook with independently reporting the flaw.
The advisory also patches other vCenter issues, including an arbitrary file-write flaw, CVE-2026-123904, rated 7.5, that could be used to achieve code execution on the appliance while processing certain archives. But the headline advice is simple: inventory every vCenter appliance, check its exact build, and patch vCenter before the hosts. Management interfaces should not be reachable from the internet or untrusted networks in any case, since exploitation needs only network access. For teams that patched in a hurry last week, the lesson is unwelcome but clear — the job is not finished until the build number matches the new advisory.