CVE-2026-124981: Mendix OIDC Flaw Allows Account Hijack

Siemens has warned that a flaw in the Mendix OIDC Provider module can let an attacker take over a user account without logging in. The company published advisory SSA-545865 on 27 November 2026, rating the flaw critical at 9.4 under version 4.0 of the CVSS scoring system, and 8.7 under version 3.1.
The vulnerability, tracked as CVE-2026-124981, sits in the module's token introspection endpoint. The module lets a Mendix app act as an OpenID Provider and an OAuth 2.0 authorisation server, and other apps use it for single sign-on and to obtain access tokens for APIs. Resource servers call the introspection endpoint to ask the provider whether an access token is valid.
How the flaw works
Affected versions do not properly check the integrity of the JSON Web Tokens sent to the introspection endpoint. Siemens says the endpoint can match a submitted token to a legitimate token record using the token's jti value alone. The jti claim is a unique identifier carried in each token, and the integrity of the rest of the token is not properly verified, which is why the flaw is classed as CWE-347, improper verification of a cryptographic signature.
An unauthenticated remote attacker who gains access to the jti value of an active token could hijack that account's session. No account and no user interaction are needed, though the attacker does need network access to the provider and the token identifier. The CVSS vectors rate attack complexity as high and scope as changed, with high impact on confidentiality and integrity and no impact on availability.
A jti value is not a secret. Token claims are encoded, not encrypted, so anything that handles an access token can read its jti. Siemens has not said how an attacker would typically obtain one. The jti claim was added in module 4.1.0 (Mendix 10.12.10 and later) and 3.3.0 (Mendix 9.24.18 and later). Mendix documentation sets the module's default access token lifetime at one hour from version 4.1.0, down from 24 hours.
Neither Siemens advisory reports exploitation in the wild, and no public proof of concept has been confirmed for this flaw. Neither advisory credits an outside researcher.
Which versions are affected
The Mendix 9 compatible branch of the module is affected in all versions before V4.3.0, and the Mendix 10 and Mendix 11 compatible branches are affected in all versions before V6.0.0. The fix is V4.3.0 or later for Mendix 9 apps, from Mendix Marketplace component 214677, and V6.0.0 or later for Mendix 10 and 11 apps, from component 244687.
The module is part of each app's model, so the fix only takes effect once the updated app is deployed. For Mendix 10 and 11 the fix is a new major version, and Mendix 10.24.0 and later already require OIDC Provider 5.0.0 or later, so teams on the 5.x line should read the module release notes before moving to 6.0.0.
What to do now
Teams should check which version of the OIDC Provider module each app includes and update every app that is behind the fixed release. They should also list every API that accepts tokens from a Mendix OIDC Provider and note whether each one relies on introspection or on signature checks.
If patching has to wait, Siemens gives one mitigation. Resource servers should verify the cryptographic signature of incoming tokens themselves, instead of relying only on the provider's introspection endpoint. That matters because the Mendix OIDC SSO module checks a token signature against the provider's published keys only when introspection is not supported, and the OIDC Provider module does publish an introspection endpoint, so an API protected by the OIDC SSO module may depend on the vulnerable endpoint by default.
A second Mendix flaw disclosed the same day
Siemens also published advisory SSA-579716 on 27 November for a separate, lower-rated flaw, CVE-2026-135278, an insufficient session expiration weakness in Mendix Runtime, rated 5.4 under CVSS 3.1 and 5.3 under CVSS 4.0. Affected Runtime versions do not end existing sessions when a user account is set to inactive, because the Runtime checks the account state only at sign-in. A deactivated user who is still signed in can keep reading and changing data within the permissions they held before deactivation. The fix is Runtime V9.24.45, V10.24.29, V11.6.13, V11.12.8 or V11.17.0, depending on the branch. Siemens lists no product-specific workaround for it.
Why it matters
Mendix authentication modules have had account-hijacking flaws before. Siemens fixed CVE-2025-40758 in the Mendix SAML module in August 2025, and CVE-2026-80465, also in the SAML module, in September 2026, revising that second advisory on 26 October 2026 because the first fixed versions did not fully remediate the flaw. The lesson for Mendix teams is to check module versions now: this flaw needs only a token identifier, not a password.